    Brand Name : QIUPU
    Model Number : KYN61
    Certification : IEC
    Price :
    Payment Terms : T/T, Western Union
    Supply Ability : 5000PCS/Month
    Delivery Time : 7 Days
    • Product Details
    • Company Profile

    High Voltage 40.5kV / 36kV Cast Resin Insulator Contact Box ( Spout )APG Technique

    CTH-40.5 40.5kV , 36kV Epoxy Resin Casting Resin Insulators ( Spout ) with KYN61 switchgear


    The solid seal column uses the APG technique, the automatic pressure gel molding of epoxy resin. It can shorten the production cycle of epoxy insulation from ten hours to ten minutes, and can control exothermic effect well. It can compensate the shrinkage caused by curing reaction, and has excellent dimensional stability and high mechanical strength.


    The maximum rated current is only 630A, and the circuit breaker can reach 3000A above(there are more than 4000A in foreign countries). The maximum rated current is only 630A, and the circuit breaker can reach 3000A or above(there are currently more than 4000A in foreign countries). The circuit breaker is usually short-circuit-protected. In case of overload, it takes a certain time(and can not be adjusted unless the internal fuse is replaced) to cut off the hot fuse of the internal fuse of the circuit, and the inner voltage switch is used to protect the overload of the device Or sulphur hexafluoride load switch.


    ItemNameRated voltage (KV)Rated frequency(Hz)Frequency withstand voltage 5 min (KV)Local discharge (pc)Creep distance (mm)Dispute bend (kN)Lighting impulse withstand voltage (KV)
    1
    3Contactor box (1250A)125045≤10>240≥880
    4Contactor box (1600A)125045≤10>240≥880
    5Wall bushing (260*395)40.55098≤10≥840≥10185

    We are specialty on epoxy resin medium voltage and high voltage components, such as 10KV, 24 KV and 40.5KV Circuit Breaker , Load breaker switch , Disconnecting Switch , Epoxy resin switchgear bushing , contactor box , insulators and transformer . 630A, 1250 A ,2500A , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and 24KV earth switch. KYN28A-12 and KYN61 high voltage switchgear components .

    Quality High Voltage 40.5kV / 36kV Cast Resin Insulator Contact Box ( Spout )APG Technique for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WENZHOU QIUPU ELECTRIC POWER CO., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)