Sign In | Join Free | My himfr.com
Home > Electrical Switchgear Components >

Armored Removable AC Metal Enclosed Switchgear Power Distribution

    Buy cheap Armored Removable AC Metal Enclosed Switchgear Power Distribution from wholesalers
     
    Buy cheap Armored Removable AC Metal Enclosed Switchgear Power Distribution from wholesalers
    • Buy cheap Armored Removable AC Metal Enclosed Switchgear Power Distribution from wholesalers

    Armored Removable AC Metal Enclosed Switchgear Power Distribution

    Ask Lasest Price
    Brand Name : Qiupu
    Model Number : KYN61
    Certification : GB17467
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000
    Delivery Time : 7 days
    • Product Details
    • Company Profile

    Armored Removable AC Metal Enclosed Switchgear Power Distribution

    KYN61-40.5 High voltage AC metal enclosed switchgear customized by professional switchgear manufacturer


    Product description


    KYN61-40.5 armored removable AC metal-enclosed switchgear (hereinafter referred to as switchgear) three-phase AC 50Hz, rated voltage 40.5kV indoor complete power distribution device. As power plants, substations, and industrial and mining enterprises to receive and distribute electric energy, it can control, protect and monitor circuits, and can also be used in places with frequent operations.
    This switchgear complies with GB3906-2006 "3~35kV AC Metal-enclosed Switchgear", GB/T11022-1999 "High Voltage Switchgear and Control Equipment Standard Common Technical Requirements" and DL/T 404-2007 "3.6kV~40.5kV AC Metal-enclosed switchgear and control equipment" and other standards.


    Model and its meaning


    ①Metal armored switchgear

    ②Removable

    ③Indoor

    ④Design serial number

    ⑤Rated voltage (kV)

    ⑥Type of circuit breaker: Z-vacuum; SF6-sulfur hexafluoride

    ⑦Rated current

    ⑧Rated short-circuit breaking current (kA)


    Scope of application

    •Ambient temperature: upper limit +40°C, and the average value measured within 24h does not exceed 35°C, lower limit -10°C; •Altitude: altitude does not exceed 1000m;
    •Relative humidity: the daily average value does not exceed 95%, and the monthly average value does not exceed 90%;
    •Earthquake intensity: no more than 8 degrees;
    • Water vapor pressure: the daily average value does not exceed 2.2kPa, and the monthly average value does not exceed 1.8kPa;
    Surrounding environment: a place where there is no fire, explosion hazard, serious pollution, chemical corrosion and severe vibration.


    Technical Parameters


    NameUnitparameter
    Rated voltagekV40.5
    Rated currentA1250 1600 2000
    Rated frequencyHz50
    Rated short-time withstand currentkA20 25 31.5
    Rated peak withstand currentkA50 63 80
    Rated power frequency withstand voltagekV95/lmin
    Rated lightning impulse withstand voltagekV185
    Rated short-circuit durations4
    Protection levelIP3X

    Installation dimension drawing



    A. Busbar room
    B. Handcart room
    C. Cable room
    D. Relay instrument room
    1. Lifting ring
    2. Main bus
    3. Cover ring for small busbar compartment
    4. Instrument room door
    5. Branch bus
    6. Bus bushing
    7. Hornworm head box
    8. Analog bus coil
    9. Nameplate
    10. Lighting
    11. Handcart room door
    12. Current transformer
    13, hairpin chain
    14. Insulator
    15. Zinc oxide arrester
    16. Insulating partition
    17. Grounding switch
    18. Valve assembly
    19. Vacuum circuit breaker handcart
    20. Small busbar terminal room


    Need to know when ordering


    Users need to provide the following information if ordering
    • The main circuit plan number, purpose, single-line system diagram, arrangement diagram and power distribution room layout diagram, etc.;
    • Auxiliary circuit wiring schematic diagram and terminal arrangement diagram;
    • The model, specification and quantity of electrical components in the switchgear;
    • Requirements for control, measurement and protection functions of switchgear, as well as requirements for other locking and automatic devices;
    • If a bus bridge connection is required between switchgears or incoming cabinets, the rated current carrying capacity of the bus bridge, the span of the bus bridge, the height from the ground and other specific requirements data should be provided; • When accessories and spare parts are needed, the types and quantities should be provided;
    • The switchgear is used in special environmental conditions and should be specified when ordering.


    Quality Armored Removable AC Metal Enclosed Switchgear Power Distribution for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WENZHOU QIUPU ELECTRIC POWER CO., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)