Sign In | Join Free | My himfr.com
Home > Electrical Switchgear Components >

ISO Armoured Electrical Switchgear Components Open Type

    Buy cheap ISO Armoured Electrical Switchgear Components Open Type from wholesalers
     
    Buy cheap ISO Armoured Electrical Switchgear Components Open Type from wholesalers
    • Buy cheap ISO Armoured Electrical Switchgear Components Open Type from wholesalers

    ISO Armoured Electrical Switchgear Components Open Type

    Ask Lasest Price
    Brand Name : Qiupu
    Model Number : YB-12/630A/1250A
    Certification : ISO,CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000
    Delivery Time : 7 days
    • Product Details
    • Company Profile

    ISO Armoured Electrical Switchgear Components Open Type

    KYN28-12 Factory Customized Sizes Long Service Life Aluminum-Zinc Plate Metal Armoured Medium Open Type Switchgear


    Product description


    KYN28-12 armored removable AC metal-enclosed switchgear is suitable for three-phase AC rated voltage 12kV, rated frequency 50Hz power system, used to receive and distribute electrical energy and control, protect and monitor the circuit.
    This product complies with GB3906 "3~35kV AC metal-enclosed switchgear", GB/T11022 "High-voltage switchgear and control equipment standard common technical requirements", IEC60298 ``rated voltage 1KV above 52KV and below AC metal enclosure switch equipment and control equipment" , DL/T404 "Indoor AC High Voltage Switchgear Ordering Technical Conditions" standard requirements.


    Model and its meaning


    ① High voltage armored switch cabinet
    ② Removable

    ③ Indoor type
    ④ Design serial number

    ⑤ Rated voltage
    ⑥ Vacuum circuit breaker

    ⑦ Spring operating mechanism
    ⑧ Rated current

    ⑨ Rated short-circuit breaking current
    ⑩ One time plan number


    Conditions of Use


    • The upper limit of ambient air temperature +40°C, the lower limit of -15°C
    • Maximum altitude of equipment installation site: 1000m
    • Environmental humidity Daily average relative humidity W 95% Monthly average relative humidity W 90%
    • The earthquake intensity does not exceed 8 degrees
    • The surrounding air should not be significantly polluted by corrosive or combustible gas, water vapor, etc.
    • No serious pollution and frequent severe vibration.


    Technical Parameters


    NameUnitparameter
    Rated voltageKV12
    Power frequency withstand voltageRated insulation levelKVBetween phases and to the ground: 42; Fracture: 48
    Lightning strikeKVBetween phases and to the ground: 75; Fracture: 85
    Rated frequencyHz50
    Circuit breaker rated currentA630, 1250, ,1600,2000,2500,3150,4000
    Switch cabinet rated currentA630, 1250, ,1600,2000,2500,3150,4000
    Rated short-circuit breaking currentkA20,25,31.5,40
    Rated short-time withstand current of main circuitkA/4s20,25,31.5,40
    Protection levelIP4X



    Installation dimension drawing



    A. Busbar room
    B. Circuit breaker handcart room
    C. Cable room
    D, relay instrument room leak pressure device
    1, 1 Waidi
    1, 2 Secondary wiring trough
    2. Branch bus
    3. Busbar casing
    4. Main bus
    5. Static contact device
    6. Static contact box
    7. Current transformer
    8. Grounding switch
    9. Cable
    10. Lightning arrester
    11. Ground bus

    12. Loading and unloading partitions
    13. Partition (trap)
    14. Secondary plug
    15. Circuit breaker handcart operating mechanism
    16. Circuit breaker handcart
    17. Withdrawable horizontal partition
    18. Grounding switch operating mechanism
    19. Bottom plate


    Need to know when ordering


    Users need to provide the following information if ordering
    • Main circuit plan number, purpose and main line system diagram, distribution room layout diagram and arrangement diagram, etc.

    • Requirements for control, measurement and protection functions of switchgear, as well as requirements for other locking and automatic devices.
    • The model, specification and quantity of the main electrical components in the switchgear.
    • If the busbar bridge connection is required between switchgear or the incoming cabinet, the rated current carrying capacity of the busbar bridge, the span of the busbar bridge, the height from the ground and other specific requirements data should be provided.
    • When the switchgear is used under special environmental conditions, it should be specified when ordering.
    • Other special requirements.